Voltage Cryptographic Module v.5.0
Caveat: When operated in FIPS mode
Certificate
| Certificate number | 2686 |
|---|---|
| Standard | FIPS 140-2 |
| Status | historical |
| Overall level | 1 |
| Module type | Software |
| Embodiment | Multi-Chip Stand Alone |
| Vendor | Micro Focus Data Security · website |
| Software versions | Version 5.0 |
Module description
The Voltage Cryptographic Module v.5.0 provides the Validated algorithms used by the SecureMail, SecureFile and SecureData families of products.
Security level exceptions
- Physical Security: N/A
- Mitigation of Other Attacks: N/A
Approved algorithms
| Algorithm | CAVP certificate |
|---|---|
| AES | 3372, 3373, 3374, 3375, 3410, 3411, 3412, 3413, 3761, 3843, 3894, 3895, 3918, 4033, 4034 |
| DRBG | 796, 797, 798, 799, 1033, 1088, 1114, 1115 |
| DSA | 1042, 1044, 1050, 1059, 1060 |
| ECDSA | 803, 806, 829, 845, 846 |
| HMAC | 2455, 2461, 2493, 2528, 2529 |
| KBKDF | 63, 67, 68, 69, 76, 83, 87, 88 |
| PBKDF | vendor affirmed |
| RSA | 1730, 1731, 1732, 1733, 1935, 1963, 1984, 1985 |
| SHS | 2791, 2792, 2793, 2794, 3131, 3166, 3210, 3211 |
| Triple-DES | 1915, 1916, 1917, 1918, 2091, 2117, 2137, 2138, 2169, 2208, 2209 |
Tested configurations
- CentOS Linux release 7.0.1406 running on a Dell Optiplex 7010 with an Intel(R) Core(TM) i7-3770 with PAA (single-user mode)
- CentOS Linux release 7.0.1406 running on a Dell Optiplex 7010 with an Intel(R) Core(TM) i7-3770 without PAA
- HP NonStop TNS/E J06.19.00 - Guardian running on an HP Integrity NonStop BladeSystem NB54000c with an Intel Itanium 9300
- HP NonStop TNS/E J06.19.00 - OSS running on an HP Integrity NonStop BladeSystem NB54000c with an Intel Itanium 9300
- HP NonStop TNS/X L15.08.00 - Guardian running on an HP Integrity NonStop X NS7 X1 with an Intel Xeon E5-2600 v2 with PAA
- HP NonStop TNS/X L15.08.00 - Guardian running on an HP Integrity NonStop X NS7 X1 with an Intel Xeon E5-2600 v2 without PAA
- HP NonStop TNS/X L15.08.00 - OSS running on an HP Integrity NonStop X NS7 X1 with an Intel Xeon E5-2600 v2 with PAA
- HP NonStop TNS/X L15.08.00 - OSS running on an HP Integrity NonStop X NS7 X1 with an Intel Xeon E5-2600 v2 without PAA
- Windows Server 2012 R2 running on a Dell Optiplex 790 with an Intel(R) Core(TM) i7-2600 with PAA
- Windows Server 2012 R2 running on a Dell Optiplex 790 with an Intel(R) Core(TM) i7-2600 without PAA
Validation history
| Date | Type | Lab |
|---|---|---|
| 2016-07-19 | Initial | AEGISOLVE, Inc. |
| 2016-08-04 | Update | AEGISOLVE, Inc. |
| 2016-08-22 | Update | AEGISOLVE, Inc. |
| 2018-10-12 | Update | Leidos Accredited Testing & Evaluation (AT&E) Lab |
| 2021-04-15 | Update | Leidos Accredited Testing & Evaluation (AT&E) Lab |
Status timeline
As observed by this tracker's snapshots. NIST publishes no dates for list moves; observation began 2026-08-21, so earlier changes carry no date.
- 2026-08-21: first observed by this tracker, status historical
- Validation dates on record: 2016-07-19, 2016-08-04, 2016-08-22, 2018-10-12, 2021-04-15